22.02.460 Required building inspections.
Reinforcing steel or structural framework of any part of any
building or structure shall not be covered or concealed without first obtaining
the approval of the building official. The building official, upon receipt of an
inspection request, shall make the following inspections:
(A) Foundation
Inspection. To be performed after excavations for footings are complete and any
required reinforcing steel, structural embeds, grounding electrodes, piping and
other equipment required by plans or code are in place before concrete is
placed. When required, a pad certification report shall be accepted by the
building official prior to performance of this inspection.
(B) Framing
Inspection. When inspection or testing is specified on an inspection agreement,
an area acceptance report shall be provided and accepted prior to inspection by
the county inspector.
(1) For Wood and Light Gauge Metal Construction. To
be performed after the roof sheathing, all framing, fire blocking and bracing
are in place and all pipes, chimneys and vents are complete and the rough
electrical, plumbing, and mechanical inspections are approved.
(2) For
Concrete, Steel and Masonry Construction. To be performed after all structural
elements required by the approved construction documents and technical codes are
in place and structural connections completed. This is to include reinforcing
steel, structural steel, concrete, masonry, grout, mortar, and all structural
connections.
(C) Lath and/or Wall Board Inspection. To be performed after
all lathing and wallboard, interior and exterior, is in place but before any
plastering is applied or before wallboard joints and fasteners are taped and
finished.
(D) Final Inspection. To be performed after finish grading and the
building is completed and ready for occupancy.
Issuance of a temporary
certificate of occupancy fulfills the one hundred eighty day permit expiration
requirement for final inspection. (Ord. 3618 § 2 (part), 2008)